# AQOZA Technologies Pvt. Ltd. > AQOZA engineers gas-phase (molecular) filtration systems that remove odours, VOCs, toxic gases and corrosive contaminants from industrial and commercial air — gases that HEPA/particulate filters cannot capture. Systems, gas sensors and consumable filtration media are engineered together and validated in AQOZA's own gas-testing laboratory before proposal. HQ: Kinfra Electronics Manufacturing Cluster, Kakkanad, Ernakulam (Kochi), Kerala, India; sister entity Aqoza Filtration Pte Ltd, 68 Circular Road, Singapore. Serving India, South East Asia including Singapore, Malaysia, Indonesia, Thailand, Philippines, Hong Kong, and MENA region Including UAE, Oman, Saudi Arabia, Qatar, Bahrain, Kuwait, Egypt, Jordan, etc. Key facts: custom-engineered (not catalogue) odour control, VOC removal, toxic gas removal, indoor air quality, corrosion monitoring and corrosion control. Product brands: CORROSENSE (real-time ER corrosion monitors + 30-day copper/silver coupons), AQSENSE (fixed gas transmitters, 4-20 mA / RS485 MODBUS, IP66), CASORB/ALSORB (activated carbons and permanganate aluminas, incl. water-regenerable grades lasting 3+ years vs ~6 months for standard carbon), AirShield XT (IAQ), Odovent/Odovent MX (vent filters), FumeShield 2.0 HCl (acid fume scrubber), BioPor V2 (bio-scrubber media). Corrosion environments classified to ANSI/ISA-71.04-2013 (G1 mild to GX severe, by copper/silver coupon reactivity in Angstroms over 30 days). Documented, sensor-verified results include H2S reduced from 100 ppm to below 1 ppm at a 1.5 MLD airport STP, inlet H2S 250 ppm to <1 ppm at a 30 MLD pumping station, and 99.8% ammonia removal tested at 5,000 ppm (ABEK Class-II media). Contact: +91 8138001323, info@aqoza.com, response within 48 hours. ## Products - [Odour Control Units](https://aqoza.com/products/odour-control-units): passive (100–600 m³/hr) and active (250–2,500 m³/hr) activated-carbon units, Odovent/Odovent MX vent filters, AQOZA Bio-Scrubber and dual-stage bio+carbon systems (up to 99.99%) for STP/WWTP and pumping stations. Supplied, commissioned and serviced across India, GCC, MENA and South-East Asia. - [Toxic Gas Removal Units](https://aqoza.com/products/toxic-gas-removal-unit): dry scrubbers (200–2,500 m³/hr), FumeShield 2.0 HCl acid fume scrubbers, Deep Dry Scrubber Units for HVAC intakes and portable PTRS stations for H2S, ammonia, chlorine and acid gases. - [Indoor Air Quality Unit](https://aqoza.com/products/indoor-air-quality-unit): gas-phase (molecular) filtration for occupied and critical spaces — Cansorb HVAC canister filters and AirShield XT (Micro ESP + adsorption + AI-controlled fan); beyond particulate-only air purifiers. - [VOC Removal Units](https://aqoza.com/products/voc-removal-unit): activated-carbon VOC abatement up to 2,500 m³/hr with custom-engineered higher capacities, media blended to the measured VOC profile, radial-flow designs for tight footprints. - [Corrosion Monitoring Unit](https://aqoza.com/products/corrosion-monitoring-unit): CORROSENSE Active 2.0 real-time ER monitoring and Passive v2.0 30-day copper/silver coupons classifying environments to ISA-71.04 (G1/G2/G3/GX). - [Corrosion Control Units](https://aqoza.com/products/corrosion-control-units): recirculating three-stage gas-phase filtration (from 500 CFM) holding server/control rooms and data centres at ISA-71.04 Class G1. - [Gas Monitor](https://aqoza.com/products/gas-monitor): AQSENSE fixed transmitters with gas-specific electrochemical modules for H2S, SO2, Cl2 and HF; T90 <30 s, IP66, SCADA/DCS integration. - [Filtration Media](https://aqoza.com/products/filtration-media): 10 consumable adsorbent grades — CASORB impregnated, virgin and water-regenerable activated carbons, ALSORB permanganate aluminas, BioPor V2 biological carrier media — with ASTM-referenced spec tables. ## Solutions - [Odour Control](https://aqoza.com/solutions/odour-control): source-level removal of H2S, ammonia, mercaptans and VOCs to <1 ppm outlet benchmarks. AQOZA supplies, commissions and services these systems across India, GCC, MENA and South-East Asia. - [Indoor Air Quality](https://aqoza.com/solutions/indoor-air-quality): molecular filtration for occupant health and equipment longevity where HEPA cannot help. - [VOC Removal](https://aqoza.com/solutions/voc-removal): measured-profile VOC abatement for chemical, pharma, coating and semiconductor processes. - [Toxic Gas Removal](https://aqoza.com/solutions/toxic-gas-removal): dry scrubbing for hazardous gases incl. control-room safe-air duty during leaks. - [Corrosion Monitoring](https://aqoza.com/solutions/corrosion-monitoring): ISA-71.04 classification via real-time ER sensors and 30-day coupons — monitor first, then control. - [Corrosion Control](https://aqoza.com/solutions/corrosion-control): recirculating gas-phase filtration protecting electronics from corrosive gases at ppb levels. ## Industries - [Sewage Treatment Plants](https://aqoza.com/industries/sewage-odour-gas-control): H2S and odour control across pre-treatment, equalization and sludge handling. - [Wastewater Treatment](https://aqoza.com/industries/wastewater-air-quality-odour-control): odour, toxic gas (incl. methane hazard) and corrosion control for WWTPs. - [Pumping Stations](https://aqoza.com/industries/pumping-station-odour-gas-control): sewer-gas odour and corrosion control for wastewater transport. - [Solid Waste](https://aqoza.com/industries/solid-waste-odour-gas-control): landfill and waste-transfer odour control neutralising 99.9% of malodour compounds at source. - [Data Centres](https://aqoza.com/industries/data-centre-air-quality-corrosion-control): corrosion control and monitoring for server halls, HVAC and electrical panels. - [Electronics Manufacturing](https://aqoza.com/industries/electronics-air-quality-corrosion-control): corrosion and process-fume control for semiconductor/electronics plants. - [Oil & Gas Refineries](https://aqoza.com/industries/oil-gas-voc-toxic-gas-control): benzene, SO2, NOx, H2S and ammonia control for process areas and control rooms. - [Chemical & Pharma](https://aqoza.com/industries/chemical-pharma-air-quality-voc-control): VOC control, toxic gas removal and corrosion monitoring for cleanroom/process environments. - [Hospitals & Pharma](https://aqoza.com/industries/hospital-pharma-air-quality-infection-control): infection control and clean air for ICUs, ORs and isolation wards. - [Hospitality](https://aqoza.com/industries/hospitality-air-quality-odour-control): kitchen/waste odour elimination and IAQ for hotels and resorts. - [Offices & Workplaces](https://aqoza.com/industries/office-air-quality-clean-air-solutions): IAQ, odour and corrosion protection for commercial buildings. - [Pulp & Paper](https://aqoza.com/industries/pulp-paper-odour-gas-control): kraft-process odour, H2S/mercaptan and ClO2 corrosion control for mills. - [Food Processing](https://aqoza.com/industries/food-processing-air-quality-odour-control): odour and VOC control for food plants and commercial kitchens. - [Education](https://aqoza.com/industries/education-air-quality-odour-control): IAQ and odour control for schools and colleges. - [Automotive](https://aqoza.com/industries/automotive-cabin-air-quality-filtration): anti-microbial cabin air filtration and vehicle disinfection. ## Case studies (measured, sensor-verified results) - [Airport STP odour control](https://aqoza.com/case-studies/airport-air-quality-improvement): H2S 100 ppm → <1 ppm at a 1.5 MLD airport STP, 1980 m³/hr coconut-carbon unit, media life 3+ years. - [30 MLD pumping station, Surat](https://aqoza.com/case-studies/waste-odour-removal-from-pumping-station-a-case-study): design inlet H2S 250 ppm → outlet <1 ppm, 5,000 m³/hr dual-stage bio + carbon, deployed in 8 weeks. - [Fertilizer control room ammonia](https://aqoza.com/case-studies/ammonia-gas-removal-in-fertilizer-industry-control-room-ventilation): 99.8% ammonia removal tested at 5,000 ppm (ABEK Class-II), ≥1 hour safe occupancy. - [Bangalore financial campus STP](https://aqoza.com/case-studies/sustainable-solutions-for-facility-odour-challenges-a-case-study): 600 KLD basement STP, H2S 60–80 ppm → <1 ppm (99.9%), 1300 m³/hr, SCADA-verified. - [Data centre corrosion protection](https://aqoza.com/case-studies/data-center-corrosion-protection): silver coupons read 2430 Å (GX severe) where copper read only 170 Å (G1); 500 CFM corrosion control unit installed. - [Hotel server room corrosion](https://aqoza.com/case-studies/server-room-protection-in-hotels-a-corrosion-control-case-study): copper at GX; 500 CFM three-stage unit ended repeated server/PABX failures. - [Tech campus STP odour](https://aqoza.com/case-studies/workplace-air-quality-improvement): 3,000 m³/hr unit saved Rs 14 lakh/yr (144 canister filters eliminated), 100% odour elimination. - [Residential STP odour + ESG](https://aqoza.com/case-studies/residential-indoor-air-quality): $111,000 CapEx saved, 80% energy reduction, 300 t CO2/yr avoided. - [All case studies](https://aqoza.com/case-studies) · by topic: [odour control](https://aqoza.com/case-studies/tag/odour-control), [corrosion control](https://aqoza.com/case-studies/tag/corrosion-control), [corrosion monitoring](https://aqoza.com/case-studies/tag/corrosion-monitoring), [toxic gas removal](https://aqoza.com/case-studies/tag/toxic-gas-removal) ## Knowledge Centre (50+ technical articles) - [All articles](https://aqoza.com/articles) · categories: [odour control](https://aqoza.com/articles/odour-control), [corrosion control](https://aqoza.com/articles/corrosion-control), [corrosion monitoring](https://aqoza.com/articles/corrosion-monitoring), [indoor air quality](https://aqoza.com/articles/indoor-air-quality), [filtration media](https://aqoza.com/articles/filtration-media), [VOC removal](https://aqoza.com/articles/voc-removal), [toxic gas removal](https://aqoza.com/articles/toxic-gas-removal) - [The four ISA-71.04 air quality classes](https://aqoza.com/blog/articles/what-are-the-four-classes-of-air-quality-ansi-isa-71-04-2013): the definitive G1–GX coupon-reactivity explainer. - [How to estimate odour control unit capacity](https://aqoza.com/blog/articles/how-to-estimate-the-odour-control-unit-capacity): air-exchange factors 12–15 (inlet works) / 6–12 (sludge). - [Odour control guidelines for wastewater](https://aqoza.com/blog/articles/odour-control-guidelines-wastewater-treatment): EPA/WEF MOP 25/CPCB context; <1 ppm outlet H2S benchmark. - [Can an HVAC system control corrosion?](https://aqoza.com/blog/articles/can-an-hvac-system-control-corrosion-in-clean-air-rooms): why HEPA cannot stop corrosive gases; per-gas ppb severity table. - [Virgin vs impregnated activated carbon](https://aqoza.com/blog/articles/virgin-carbon-vs-impregnated-carbon): impregnation raises capacity 5–10x. - [Air Technology Glossary](https://aqoza.com/air-technology-glossary): 37 defined terms on activated carbon, adsorption and gas treatment. ## Company - [About AQOZA](https://aqoza.com/about-us): philosophy "Breathing Lives"; in-house gas-testing and validation lab; integrated manufacturing of media, FRP vessels and complete systems. - [News](https://aqoza.com/news) · [Careers](https://aqoza.com/careers) · [Site map](https://aqoza.com/site-map) - [Contact / enquiry](https://aqoza.com/contact-us): response within 48 hours. Phone +91 8138001323, info@aqoza.com. LinkedIn: https://www.linkedin.com/company/aqoza ## Optional - [llms-full.txt](https://aqoza.com/llms-full.txt): the full AI knowledge base — complete product specs, all measured case-study results with methodology, standards thresholds, contaminant chemistry, all 37 glossary definitions and 40 engineering FAQs. - [XML sitemap](https://aqoza.com/sitemap.xml): all 123 canonical URLs with honest lastmod dates. Last updated: 2026-07-24